Is Your Building Actually Fire Compliant?
Most building owners assume they are. Most are wrong about at least three things. Our free compliance check takes one visit and tells you exactly where you stand β across every fire protection system in your building.
Across fire extinguishers Β· hose reels Β· hydrants Β· detection Β· suppression Β· ventilation Β· fire doors Β· escape plans
The Compliance Question
Can You Honestly Answer Yes?
Before you say “yes, we’re compliant” β work through these questions for your building. If you hesitate on even a few, you need this check.
SANS 1475 Β· SANS 10105
? Are all extinguishers serviced within the last 12 months by a registered service provider β with labels to prove it?
? Is the correct extinguisher type installed in each area β Class A, B, C or COβ for electrical risks?
? Is there adequate coverage β one unit per 200mΒ² for Class A risks β and are all units accessible and unobstructed?
? Has the 5-year hydrostatic pressure test been conducted on all cylinders that require it?
Most buildings have extinguishers. Few have the right type, in the right place, with current service records.
SANS 543 Β· SANS 10400-T
? Can a 30-metre hose reach every point on the floor from at least one reel β are there coverage gaps?
? Has each reel been pressure tested and flow tested within the required maintenance interval?
? Is the hose in good condition β no kinks, perishing, or sections that won’t fully retract?
? Are shut-off valves and swing arms operational and not seized from disuse?
Hose reels are often overlooked at service β and coverage gaps are rarely checked until an inspector measures them.
SANS 1128 Β· SANS 10400-T
? Are all hydrant valve boxes clearly marked, accessible and unobstructed by storage, vehicles or landscaping?
? Are booster connection inlets capped, accessible and clearly identified for fire brigade use?
? Has the system been pressure and flow tested to confirm the municipality supply can meet fire brigade demand?
? Are wet and dry riser systems (if present) serviced, tested and certified?
Hydrant systems are typically only discovered to be non-functional when the fire brigade needs them most.
SANS 10400-T Β· EN 12101
? Have smoke vents or AOVs been tested for correct automatic actuation recently?
? Is the smoke ventilation system integrated correctly with the fire alarm β and does it trigger on the right zones?
? Are manual override controls accessible, labelled and functional for fire brigade use?
? Has the system been commissioned, with a commissioning certificate on file?
Smoke ventilation is rarely maintained between installations. Actuators seize. Override controls are forgotten.
SANS 10139:2021
? Has your system been serviced by a competent person within the last 6 months β with a servicing certificate issued?
? Do you know the declared SANS 10139 category of your system β M, L, or P β and is it documented?
? Has your false alarm rate exceeded 1 per 25 detectors per annum β which triggers a mandatory investigation?
? Do you hold design, installation, and commissioning certificates for your system?
Most fire alarm systems in South Africa are operating without a declared category and with overdue service records.
SANS 14520 Β· NFPA 2001
? Are all suppression cylinders within specified weight tolerance and pressure range β verified within the last 6 months?
? Has a room integrity test been conducted to confirm the protected space can hold the agent concentration?
? Are pre-discharge alarms and abort switches functional and clearly labelled?
? Is the system in automatic mode β not manually isolated or on maintenance bypass β right now?
Gas suppression systems protect your highest-value assets. Yet room integrity failures and cylinder degradation are common.
SANS 10400-T Β· SANS 1253
? Do all fire doors self-close and positively latch β with no gaps that would allow smoke or fire to pass?
? Are intumescent seals intact and undamaged β not painted over, compressed or missing?
? Are any fire doors being held open with wedges or props that are not approved electromagnetic hold-opens?
? Have any fire doors been modified or had holes drilled through them β compromising their fire rating?
Propped-open fire doors are one of the most common and most dangerous non-compliances found in any building survey.
SANS 23601:2010
? Are escape plans displayed at every floor entry, near lifts and stairs, at junctions β permanently fixed?
? Are they minimum A3 size, colour-coded with a “You Are Here” marker in safety blue and ISO 7010 signs?
? Have they been updated since your last renovation, layout change, or equipment move?
? Is the orientation correct β does left on the plan correspond to the viewer’s actual left at each point?
A generic floor plan is not a SANS 23601 escape plan. Most displayed plans fail multiple mandatory requirements.
How many of those could you confidently answer?
If you paused on any of them β or realised you genuinely don’t know β that is exactly what the free compliance check is designed to find.
What We Assess
Eight Systems. One Visit.
Our technicians are trained across every fire protection system governed by SANS 10400-T. One visit covers your entire fire protection picture.
Type, coverage, condition, service records, pressure test status and accessibility.
SANS 1475 Β· SANS 10105
Coverage radius, hose condition, pressure, valve and swing arm operation, service history.
SANS 543 Β· SANS 10400-T
Accessibility, valve condition, booster connections, riser systems and brigade access.
SANS 1128 Β· SANS 10400-T
Actuator operation, alarm integration, manual override and commissioning status.
SANS 10400-T Β· EN 12101
System category, service frequency, certificate status and false alarm rate.
SANS 10139:2021
Cylinder weights, pressure, room integrity, discharge indicators and abort systems.
SANS 14520 Β· NFPA 2001
Self-closing, latching, intumescent seals, held-open status and frame integrity.
SANS 10400-T Β· SANS 1253
SANS 23601 compliance β size, colour coding, You Are Here, orientation and placement.
SANS 23601:2010
What We Typically Find
Non-Compliance Is More Common Than You Think
Buildings are rarely fully compliant. The reality is almost always a mixed picture. Our job is to show you exactly what the picture is.
9/10
Buildings have at least one non-compliant system on first assessment
7/10
Fire detection systems have no declared SANS 10139 category
6/10
Extinguishers have at least one compliance issue
8/10
Escape plans fail SANS 23601 requirements
The Process
Simple, Fast, No Disruption.
No preparation required, no staff disruption, and no commercial pressure. You get the truth about your building.
01. Book Online
02. We Visit Your Building
03. You Get Your Report
What’s Included β At No Cost
What You Get From the Free Check
Everything below is provided at no charge and with no obligation to engage Altrafire for any work.
- β On-site assessment across all 8 systems β visual and functional check by a trained technician
- β Written compliance report β system-by-system findings with SANS references
- β Risk priority rating per finding β Critical, High, or Advisory
- β Photographic documentation of key non-compliances
- β Regulatory context per finding, linked to the specific SANS clause
- β Report walkthrough briefing β clarity, not paperwork
What this is not: a formal SANS 10400-T audit or legal certification. Think of it as a health check, not a diagnosis certificate.
Book Your Free Check
Tell Us About Your Building
Takes 2 minutes. We’ll confirm availability and be on site within the week.
Before You Book
A Few Things People Usually Ask
Is there really no cost or obligation?
How is this different from a full fire risk assessment?
What happens after the check β will I be pressured to buy?
How long does the visit take?
Do I need to prepare anything?
You Won’t Know Until Someone Checks.
The gap between “we have fire protection” and “we are fire compliant” is where most buildings live. Our free check shows you exactly where that gap is β before an inspector, insurer or incident does it for you.